La description

Sensor head Maximum rated flow rate 1 L/min
Model FD-XS1
Supported pipe materials Metal pipes, Plastic pipes (soft/hard) *1
Supported fluids Liquids (water, oil, adhesive, grease, chemical solution, etc.) *1
Supported fluid temperature 0 °C (no freezing on the pipe surface) to 100 °C (Pipe surface temperature)
Clamp set model Plastic pipe/tube attachment FD-XC1R1, FD-XC1R2
Metal pipe attachment FD-XC1M
Maximum rated flow rate 0 to 1000 mL/min
Zero cut flow rate 20 mL/min*2 (variable, default)
Display resolution Instantaneous flow rate 0.1/1/10 mL/min (Displayed on controller)
Shot amount 0.001/0.01/0.1/1 mL (Displayed on controller)
Repeatability Plastic pipe /tube attachment Response time: 50 ms F.S. ±0.6 %*3*4
Instantaneous flow rate ±6 mL/min*3*4
Response time: 500 ms ±1.9 mL/min*3
Metal pipe attachment Response time: 50 ms F.S. ±1 %*3*4
Instantaneous flow rate ±10 mL/min*3*4
Response time: 500 ms ±3.2 mL/min*3
Hysteresis Variable
Integrated unit display 0.1/1/10/100/1000/10000 mL (displayed on controller)
Display method Status indicator
Environmental resistance Enclosure rating IP65/IP67 (IEC60529) , IP68G (JIS C0920) *5
Operating ambient temperature 0 to 60 °C (No freezing)
Operating ambient humidity 35 % to 85 %RH (No condensation)
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X,Y,Z direction
Shock resistance 50 G 11 ms, 3 times each for X,Y,Z direction
Material Sensor head Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM
Clamp set For plastic pipe Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7
For metal pipe Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7
Weight Approx. 230 g
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe. *2 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *3 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range. *4 The longer the response time is set, the more repeatability is improved. As a guideline, use v (50 ms/response time) times. *5 The connector part of the sensor head cable is IP65/IP67.
''