La description

Amplifier Unit
Model LX2-V10W
Display range -19,999 to +19,999
Sampling rate 12,500 /sec
Control input Laser remote NPN open collector or non-voltage contact signal
Output Controloutput NPN open collector: 100 mA max. (40 V max.)
Response time 0.16 ms*1
Analogue output Output voltage 0 to 5 V
Impedance 100 ?
Temperature characteristics 0.1 % of F.S./ °C*2
Major functions Reference light quantity entry, Auto Gain adjustment, auto scaling, manual scaling, auto-zero, offset, data processing (10 modes), etc.
Rating Power voltage 24 VDC ±10 %
Current consumption 190 mA or less
Environmental resistance Ambient temperature 0 to +50 °C (No condensation)
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 220 g
*1 Data obtained when the number of measurements to average is set to 1 *2 Typical data obtained when the sensor head is connected. The temperature characteristic obtained when connecting the LX2- 110 (W) is 0.2% of F.S./°C.
''