La description

Sensor Amplifier for IV-HG, Main unit
Model IV-HG10
Type Main unit
Tools Type Shape Detection, Area*1, Colour Area*2, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment), OCR*3
Number Detection tools: 16 tools, position adjustment tool: 1 tool*4
Switch settings (programs) 32 programmes
Image history Numbers When using a colour type head: 100 images*5, when using a monochrome type head: 300 images*6*7
Condition NG only/All is selectable*7
Analysis information OFF/Statistics/Histograms/Matching rate list is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs Matching rate list: Judgment results list by tools, matching rate list by tools, judgment bar list by tools*8
Other functions HDR, HighGain, Colour filters*2, Digital zoom (2x, 4x)*9, Brightness correction, Tilt correction, White balance*2, Mask function, Colour histogram, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Direct connection (2 units or more), Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold
Indicators PWR/ERR, OUT, TRIG, STATUS, LINK/ACT
Input Type Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Inputs 6 inputs (IN1 to IN6)
Function IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Programme switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input
Output Type Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-HG15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-HG15]), remaining voltage 2 V or lower
Outputs 8 outputs (OUT1 to OUT8)
Function Enable by assigning the optional functions Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool, Result of the logical operation of each tool, Main unit/expansion unit logical output
Ethernet Standard 100BASE-TX/10BASE-T*10
Connector RJ-45 8pin connector*10
Network function FTP client, EtherNet/IPTM, PROFINET
Rating Power voltage 24 VDC ±10 % (including ripple)
Current consumption 0.8 A or less. 1.5 A or less when also using an expansion unit (IV-HG15). (The output load is excluded.)
Environmental resistance Ambient temperature 0 to +50 °C (No freezing)*11
Relative humidity 35 to 85 % RH (No condensation)
Material Main unit case: Polycarbonate
Weight Approx. 150 g
*1 Monochrome type only *2 Colour type only *3 Supported with Ver. R5.00.00 or later. *4 Tools can be installed by programmes. *5 When using the FTP client function: 70 pictures *6 When using the FTP client function: 210 pictures *7 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV-H/IV-HG Series (IV-H1). *8 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV-H/IV-HG Series (IV-H1). *9 Possible with both the colour type and monochrome type *10 This is for connection with the intelligent monitor (IV-M30) or software for the IV-H/IV-HG Series (IV-H1). *11 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate.
''