La description

Terminal Block Unit
Model FS-R3
Response time 350 µs to 1 ms *1
Indicator lamp Red LED
Timer function
Number of inputs 2
Input signal NPN/PNP non-voltage input (contact,solid-state) switching
Output mode N.O./N.C. (selectable)
Rating Power voltage 12 to 24 VDC ±5 %, Ripple (P-P) 5 % or less*2
Current consumption 50 mA or less, plus current consumed by connected sensor (100 mA or less)
Environmental resistance Ambient temperature -10 to +50 °C (No freezing)*3
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Polycarbonate
Weight Approx. 30 g
*1 The response speed varies depending on the number of expansion units connected. *2 Change the supply voltage to meet the requirement of the input device (PLC, etc.). *3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 1 to 5 Units: -10 to +50 °C, 6 to 8 Units: -10 to +45 °C.
''