La description

Amplifier Unit, DC Type, NPN
Model ES-X38
Type DC
Operation mode N.O./N.C. (switch-selectable)
Indicator Output: Red LED
Output Control output NPN: 100 mA (40 V) max. Residual voltage: 1 V max.
Disconnection alarm output NPN: 100 mA (40 V) max. Residual voltage: 1 V max.*1
Leakage current (OFF time) ?
Response time 1 ms max.
Temperature characteristics ±8% of detecting distance at 23°C within 0 to 50°C
Sensitivity adjustment 15-turn trimmer
Rating Power voltage 12 to 24 VDC, Ripple (P-P) 10 % or less
Current/power consumption 25 mA max.
Environmental resistance Ambient temperature 0 to +50 °C
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 67 g (including 2-m cable)
*1 La salida de alarma de interrupcion de conexion no esta disponible en ES-M2 (P).
''