La description

Application Unit
Model SL-R12EX
Power supply Supplied by SL-R11 or SL-U2
Input Muting input Maximum input voltage 26.4 VDC
Input rating 24 VDC 2.3 mA
Threshold voltage (ON) 19 V
Threshold current (OFF) 0.5 mA
Common ground A common for A1 and A2, a common for B1 and B2
Bank selection input Maximum input voltage 26.4 VDC
Input rating 24 VDC 1.6 mA
Threshold voltage (ON) 19 V
Threshold current (OFF) 0.5 mA
Common ground A common for A1, A2 and A3, a common for B1, B2 and B3
Allowance for 2 inputs timing gap 200 ms max.
Output for muting lamp 24 VDC 15 mA to 300 mA
Rating Current consumption 110 mA or less (including 24 VDC, SL-R12D)
Environmental resistance Enclosure rating IP20 (IEC60529) Mount in a control panels at least IP54
Ambient temperature -10 to +55 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Polycarbonate
Weight Approx. 300 g
''