La description

Safety Control Unit
Model SL-R11
Response speed FSD1, 2 AUX 24 ms (including sensor response time)*1
Safety light curtain SL-C Series
FSD 1,2 230 VAC 4 A 30 VDC 2 A (resistive load) 230 VAC 2 A (cos O = 0.3) (inductive load) 30 VDC 1 A (cos O = 0.3) (inductive load)
SL-R11 output Lifespan Mechanical life: 10 million times min. Electrical life: 100000 times min.
Response speed when E-STOP is input 20 ms
AUX 125 VAC 0.5 A 30 VDC 2 A (resistive load) 125 VAC 0.25 A (cos O = 0.3) (inductive load) 30 VDC 1 A (cos O = 0.3) (inductive load)
Approved standards EMC EMS UL61496-1*2
EMI FCC Part 15 Class A*2
Safety UL61496-1 (type 4 ESPE) UL61496-2 (type 4 AOPD) UL508*2
Rating Power voltage 24 VDC ±10 %, Ripple (P-P) 10 % or less
Current consumption 150 mA or less (for SL-R11 only)
Environmental resistance Enclosure rating IP20 (IEC60529) Install in control panels which is equal to or greater than IP54
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -10 to +60 °C (No condensation
Operating relative humidity 35 to 85 % RH (No condensation)
Storage relative humidity 35 to 95 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Polycarbonate
Weight Approx. 380 g
*1 The OFF > ON return time is 150 ms. *2 Evaluated in combination with the SL-C Series.
''