La description

Safety Relay Terminal
Model GL-T11R
Applicable model GL-R Series
Relay output FSD1,2 250 VAC 6 A 30 VDC 6 A (Resistance load) 240 VAC 2 A (COSo=0.3) (Inductive load) 24 VDC 1 A (COSo=0.3) (Inductive load)
Life-span Electrical life-span 100,000 cycles or more with 250 VAC 6 A resistance load (open/close frequency: 20 times/minute) 100,000 cycles or more with 30 VDC 6 A resistance load (open/close frequency: 20 times/minute) 500,000 cycles or more with 250 VAC 1 A resistance load (open/close frequency: 30 times/minute) 500,000 cycles or more with 30 VDC 1 A resistance load (open/close frequency: 30 times/minute) AC15: 100,000 cycles or more with 240 VAC 2 A inductive load (open/close frequency: 20 times/minute, coso = 0.3) DC13: 100,000 cycles or more with 24 VDC 1 A inductive load (open/close frequency: 20 times/minute, L/R = 48 ms)
Response time ON>OFF GL-R +10 ms
OFF>ON GL-R +32 ms
Supplemental output (Non-safety-related output) AUX Transistor output (PNP/NPN input device can be connected.)*1 50 mA max., residual voltage 2.5 V max. (When the cable between the GL-R and GL-T11R is 5 m)
Error output
Muting lamp output Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected.
External input EDM inputWait inputReset inputMuting input 1, 2Override input ON voltage: [Power supply voltage - 5 V] to [Power supply voltage] OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
Rating Power voltage 24 VDC ±10%, ripple (P-P) 10% or less, Class 2
Current consumption 100 mA max. (24 VDC, GL-T11R only)
Approved standards EMC EMS EN61496-1, UL61496-1, IEC61496-1
EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Safety EN61496-1, UL61496-1, IEC61496-1 (Type4 ESPE) EN ISO13849-1 : 2015 (Category4, PLe) UL508, EN50178
Environmental resistance Enclosure rating IP20 (IEC60529) Must be installed within a control panel rated at IP54 or higher.
Pollution degree 2
Overvoltage category III
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 15 to 85 % RH (No condensation)
Storage relative humidity 15 to 95 % RH
Altitude 2,000 m or less
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Main unit case Polycarbonate
Weight Approx. 310 g
*1 The output operation is the same as that when the PNP output type cable is used.
''